Add Emergency Mass Notification Messages and Alerts to your School District


Viking Digital Mass Notification Announcer with alert tones messages & live page

 
HORN.jpg
 

EMERGENCY CONDITION

"May I have your attention, please. May I have your attention, please. An emergency condition exists in this building. An emergency condition exists in this building. Please proceed to the stairways and exit the building. Do not use the elevators."


User Recorded Message Script Examples

The following are some examples of messages which may be recorded in the field:

 
 
 
 
DNA-510.png

Applications

Provide Emergency Mass Notification for:

  • Schools

  • College Campuses

  • Restaurants

  • Churches

  • Theaters

  • Auditoriums

  • Dormitories

  • Office buildings

  • Factories

  • Any “area of assembly”

Product Details

  • Can be programmed with 10 different alert tones for emergency mass notification of evacuation, lockdown, severe weather, fire, bomb threat, hazardous material release, tornado, flash flood, terrorist alert, all-clear, etc.

  • Capable of providing up to 2 minutes of digitally recorded voice emergency instructions and alert tones over your existing paging system.

  • Connects to a phone line, analog phone system station or a phone system’s unused trunk/line input allowing you to securely page, trigger emergency messages and/or alert tones and program the unit from any remote touch tone phone.

  • When activated, it will interrupt any current paging or background music and inject an emergency voice message and/or alert tone over your paging system. A live page can also be announced.

  • Can be programmed to repeat one up to 2 minute message, two up to 1 minute messages, three up to 40 second messages, four up to 30 second messages or five up to 24 second messages.

Features

  • Non-volatile memory, no batteries required

  • Up to 2 minutes of total message record time

  • Record up to 5 different emergency messages

  • Ten different emergency alert tones:

    • Hi/Low Siren

    • Code 3 Temporal (ANSI S3.41) Slow Whoop

    • Attack Wail*

    • Alert Siren*

    • Fast Wail*

    • Fast Whoop

    • March Time Horn

    • Bell*

    • Buzzer

    • All Clear Tone

*Note: Looping recordings of actual emergency sirens and alarm bell.

  • Call progress detection for automatic hang up on CPC, busy signal, dial tone or 20 seconds of silence (during live page only)

  • Separate volume controls for paging, messages and alert tones

  • Automatically interrupts current page or background music to inject emergency announcement, alert tones or live page

  • Programmable trigger input to activate a message and / or alert tone

  • SPDT trigger output contacts for activating flashing beacon (BLK-4-EWP), Alarm Dialer (K-202-DVA), etc.

  • Access code to prevent fraudulent use

  • Connects directly to an unused line input (trunk) or station port of a phone system or to a dedicated phone line


 
SL-2-EWP.png

Viking Beacon Visual Indicator

LED Strobe and/or Beacon Visual Indicator with Programmable Brightness and Flash Patterns, and Enhanced Weather Protection

Applications

  • High noise level areas where visual status is required

  • Signal personnel of equipment malfunctions

  • Warn personnel they are entering a restricted area

Features

  • Durable polycarbonate lens

  • High-output long life LED technology

  • Four programmable flash patterns:

    • Single Flash

    • Double Flash

    • Quad Flash

    • Flicker Flash

  • 6 programmable beacon and strobe brightness settings

  • Immune to shock and vibration

  • Low current draw

  • Shatter resistant polycarbonate lens

  • Enhanced Weather Protection (EWP), EWP products are designed to meet IP66 Ingress Protection Rating

Product Details

The SL-2-EWP is a 360° LED Strobe and/or Beacon visual indicator. LED’s not only are more efficient and last longer than standard flash tubes but are also immune to shock and vibration. The LED’s are internally positioned to allow a 360° viewing angle when the unit is mounted vertically and a 120° viewing angle when side mounted.

The SL-2-EWP can be user programmed to output 4 different flash patterns: Single Flash, Double Flash, Quad Flash or Flicker Flash. The unit can also be programmed as a continuous-On Beacon only, Strobe only or Beacon/Strobe allowing a lower intensity beacon to remain on and a high intensity strobe to be activated by a contact closure. 6 different brightness levels are also programmable for the Beacon and the Strobe. All programming is stored in non-volatile memory so you won’t lose the programming when the unit is powered down, allowing you to program units prior to installation.

The SL-2-EWP is designed for indoor applications and comes standard with a Blue shatter resistant polycarbonate lens. Optional Red, Amber, Green and Clear lenses are sold separately (go to www.vikingelectronics.com and click on spare parts). Unit surface mounts to wall, post, panel, 4” electrical box or wet location electrical box round lamp holder cover.

The SL-2-EWP is equipped with Enhanced Weather Protection (EWP), ideal for outdoor installations where the unit is exposed to precipitation or condensation. EWP products feature foam rubber gaskets, sealed connections, gel-filled butt connectors, as well as urethane or thermal plastic potted circuit boards.